Official ESCRS | European Society of Cataract & Refractive Surgeons
London 2014 Registration Visa Letters Programme Satellite Meetings Glaucoma Day 2014 Exhibition Hotel Booking Virtual Exhibition Star Alliance
london escrs

Course handouts are now available
Click here


Come to London

video-icon

WATCH to find out why


Site updates:

Programme Updates. Programme Overview and - Video Symposium on Challenging Cases now available.


Influence of posterior astigmatism on the estimation accuracy of residual astigmatism after toric lenses implantation

Search Abstracts by author or title
(results will display both Free Papers & Poster)

Session Details

Session Title: Cataract Surgery Outcomes

Session Date/Time: Tuesday 16/09/2014 | 08:00-10:30

Paper Time: 09:14

Venue: Capital Hall A

First Author: : Q.De Bosredon FRANCE

Co Author(s): :    G. Mello   M. Santhiago   T. de Castro   D. Smadja     

Abstract Details

Purpose:

To determine whether the consideration of the posterior astigmatism in the toric iol calculation provides a more accurate estimation of the postoperative residual astigmatism (RA).

Setting:

Bordeaux Hospital University

Methods:

A total of 30 eyes of 20 patients candidates for toric lense implantation were prospectively enrolled in this study. The thirty lenses were calculated with two different calculations methods. The standard method, using the simulated anterior astigmatism (SimAA) measured with a Dual Scheimpflug system (Galilei, Ziemer) and the alternative method that uses the total corneal astigmatism (TCA) measured with ray tracing. The achieved residual astigmatism (magnitude and axis) at 3 month postoperatively was compared to the estimated residual astigmatism calculated with the standard method or the ray tracing method.

Results:

The average preoperative corneal astigmatism was measured at 1.8D with the SimAA, and at 1.46D with TCA (p< 0.05). The mean magnitude of achieved residual astigmatism at 3 months was 0.16 +/- 0.24 D, whereas the mean estimated residual astigmatism was expected to be 0.5 +/- 0.32 D when using the SimAA and 0.28 +/- 27D when using the TCA. The mean difference between the estimated and the achieved RA was significantly greater (p< 0.05) when using the SimAA (0.25 +/- 0.3D) than that with TCA (0.08 +/- 0.16D).

Conclusions:

The use of the simulated anterior astigmatism rather than the total corneal astigmatism in the toric lenses calculation is less accurate and leads to an overestimation of the expected residual astigmatism, which might ultimately flip the cylinder axis in some cases.

Financial Interest:

NONE

Back to previous