Official ESCRS | European Society of Cataract & Refractive Surgeons
London 2014 Registration Visa Letters Programme Satellite Meetings Glaucoma Day 2014 Exhibition Hotel Booking Virtual Exhibition Star Alliance
london escrs

Course handouts are now available
Click here


Come to London

video-icon

WATCH to find out why


Site updates:

Programme Updates. Programme Overview and - Video Symposium on Challenging Cases now available.


First results after lens exchange with implantation of two different types of multifocal IOL: FineVision trifocal (PhysIOL) and B1EWYN progressive (1st Q) – a comparative study

Search Abstracts by author or title
(results will display both Free Papers & Poster)

Session Details

Session Title: Pseudophakic IOLs/ Multifocals II

Session Date/Time: Tuesday 16/09/2014 | 08:00-10:30

Paper Time: 09:10

Venue: Boulevard A

First Author: : M.Costin Ilie GERMANY

Co Author(s): :    M. Poelzl   D. Holland   D. Uthoff        

Abstract Details

Purpose:

The aim of the retrospective study was to compare the results of the intermediate-near- and distance visual acuity and the resulting target refraction after bilateral cataract surgery for both IOLs.

Setting:

Eye Hospital Bellevue, Kiel, Germany

Methods:

We analyzed a group of thirty-nine patients/78 eyes (Range 65 to 79 years) after bilateral cataract surgery. Thirty-six eyes of eighteen patients were implanted with the B1EWYN Progressive IOL and forty-two eyes of twenty-one patients were implanted with the FineVision trifocal IOL. The mean preoperative monocular CDVA was 0.23/0.26 logMAR (Progressive/Fine Vision IOL). We measured the following parameters postoperatively: corrected and uncorrected, monocular and binocular distance visual acuity (UDVA and CDVA), the uncorrected and distance-corrected intermediate visual acuity (UIVA and DCIVA) at a 60 and 80 cm distance, the uncorrected and distance-corrected near visual acuity (UNVA and DCNVA) at a 40 cm distance and the achieved target refraction.

Results:

The mean UDVA was monocular 0.09/0.11 logMAR (Progressive /Fine Vision IOL) and binocular -0.01/0.02 logMAR; the mean CDVA monocular was -0.03/0.02 logMAR. The mean UIVA was monocular at 60 cm 0.33/0.39 logMAR, binocular 0.23/0.30 logMAR ; the mean DCIVA monocular was 0.37/0.38 logMAR. The mean UIVA was monocular at 80 cm 0.29/0.36 logMAR and binocular 0.21/0.25 logMAR; the mean DCIVA monocular was 0.31/0.34 logMAR. The mean UNVA was monocular 0.18/0.27 logMAR , binocular 0.09/0.14 logMAR; the mean DCNVA monocular was 0.13/0.24 logMAR.The averege residual spherical equivalent was 0.22 ± 0.54 Dpt/0.07 ± 0.36 Dpt and the Δ (achieved/attempted) residual spherical equivalent was 0.11/0.08 Dpt (Progressive /Fine Vision IOL)

Conclusions:

The mean results demonstrate a satisfactory postoperative visual quality and acuity in all distances (near, intermediate, distance).The postoperative average residual spherical equivalent of the Progressive lens shows a wider deviation from the target of emmetropia, in comparison to the Fine vision lens. Taking this difference into consideration, the biometrical settings were optimized.

Financial Interest:

NONE

Financial Interest:

NONE

Back to previous