Outcomes following the correction of high astigmatism with toric multifocal IOL in cataract surgery
(results will display both Free Papers & Poster)
Session Details
Session Title: Interactive Free Paper Session: Pseudophakic IOLs/ Toric
Session Date/Time: Monday 15/09/2014 | 16:30-18:30
Paper Time: 18:04
Venue: Capital Hall B
First Author: : J.Chawla UK
Co Author(s): :
Abstract Details
Purpose:
To analyse the results of refractive toric multifocal intraocular lens implant with rotational asymmetry
Setting:
Spire Hartswood Hospital, Brentwood, Essex United Kingdom
Methods:
38 eyes of 19 patients with cataract and high astigmatism ranging from 1 to 5 dioptres of astigmatism were included in the study. All patients received toric multifocal IOL with surface embedded 3 dioptre sector shaped near segment inferiorly (Lentis M Plus Toric). IOL calculations were performed using web based online calculator. Uncorrected distance and near vision, corrected distance and near vision, auto refraction, subjective refraction were recorded pre- and post operatively.
Results:
95% patients achieved uniocular unaided vision of 0.00 for distance and N6 for near. Binocular vision of 0.00 for distance and N6 for near was achieved in 98% of patients. High satisfaction rates (98%) was achieved in satisfaction surveys post operatively.
Conclusions:
Toric multifocal IOL in cataract surgery gave good refractive and visual outcomes and spectacle independence was achieved in majority of patients.
Financial Interest:
NONE