Programme Updates. Programme Overview and - Video Symposium on Challenging Cases now available.
Modified capsular tension ring injector system
(results will display both Free Papers & Poster)
Session Details
Session Title: Cat Surgery Equip/Phaco
Session Date/Time: Monday 15/09/2014 | 14:30-16:00
Paper Time: 15:30
Venue: Boulevard F (Level 1)
First Author: : S.Gupta INDIA
Co Author(s): :
Abstract Details
Purpose:
Design and Use of new Capsular Tension Ring (CTR) injection system
Setting:
Alo Eye Care, Kolkata
Methods:
: A CTR injector was designed from a 20G IV catheter. The eye of CTR was threaded with suture 10-0 Nylon /Prolene. CTR was injected into the eye through the main phaco port in a folded manner through 2.2 and 2.8 mm incisions. The sutures were removed only after completion of surgery.
Results:
The CTR insertion was smooth. Threading allowed slow and guided release of CTR in the bag and safe recovery if CTR removal was required in case of PCR. No extra complications were noted.
Conclusions:
New CTR delivery system is easy to make and use; is reproducible and safe to use. It also allows safe and easy removal preoperatively if need be.
Financial Interest:
NONE