Clinical results of Hoffer H-5 formula: 3000 eye global study
(results will display both Free Papers & Poster)
Session Details
Session Title: Cataract: Special Cases
Session Date/Time: Monday 15/09/2014 | 17:00-18:30
Paper Time: 17:12
Venue: Boulevard B
First Author: : K.Hoffer USA
Co Author(s): : G. Savini
Abstract Details
Purpose:
To evaluate the IOL power prediction accuracy of the new Hoffer H-5 formula compared to other modern formula.
Setting:
Clinical practices from 50 surgeons from around the world.
Methods:
Data was collected from many surgical practices from around the globe including biometry data as well as race and gender of the patient. Calculation of the prediction accuracy was done for the H-5, Haigis, Hoffer Q, Holladay 1 and SRK/T formulas using MedAE after adjusting all MEs to zero.
Results:
These calculations will be complete by the time of the meeting and fully presented. There may be well over 3000 eyes.
Conclusions:
The results will show the accuracy of this new formula compared to the others used today.