Official ESCRS | European Society of Cataract & Refractive Surgeons
London 2014 Registration Visa Letters Programme Satellite Meetings Glaucoma Day 2014 Exhibition Hotel Booking Virtual Exhibition Star Alliance
london escrs

Course handouts are now available
Click here


Come to London

video-icon

WATCH to find out why


Site updates:

Programme Updates. Programme Overview and - Video Symposium on Challenging Cases now available.


Comparison of incision integrity and morphological features following IOL implantation with three injector devices: randomized clinical trial

Search Abstracts by author or title
(results will display both Free Papers & Poster)

Session Details

Session Title: Cataract Surgery/ Equip/ IOLs

Session Date/Time: Sunday 14/09/2014 | 14:30-16:00

Paper Time: 14:42

Venue: Capital Hall B

First Author: : S.Vasavada INDIA

Co Author(s): :    V. Vasavada   A. Vasavada   S. Raj   V. Vasavada   S. Srivastava  

Abstract Details

Purpose:

Evaluate and compare incision enlargement as well as ingress of trypan blue from the ocular surface into the anterior chamber following implantation of a foldable hydrophobic acrylic intraocular lens (IOL) through a 2.2mm clear corneal incision(CCI) using one automated and two manual injector systems

Setting:

Iladevi Cataract & IOL Research Centre, Raghudeep Eye Hospital,

Methods:

Randomized clinical trial in120 eyes(120 patients)undergoing microcoaxial phacoemulsification through a 2.2mm CCI randomized to three groups depending on IOL injector used:Group I(n=40),where automated motorized injector(Autosert®) used;Group II(n=40),where a plunger type injector(Royale)used;Group III(n=40),screw type injector(Monarch III)used.Incision widths were measured before and after implantation of a foldable,single-piece aspheric hydrophobic acrylic IOL using D cartridge.Following IOL implantation and stromal hydration,trypan blue 0.0125% was applied over the conjunctival surface,and ingress compared.Architectural features of CCIs were evaluated using anterior segment OCT(AS-OCT) on postoperative day 1,1week and 1month

Results:

Ongoing study,results of 60 eyes presented,results will be updated.Incision enlargement from end of phacoemulsification to IOL implantation:Group I(n=19):0.07+0.05, Group II(n=18):0.16+0.05,Group III(23):0.22+0.04;difference being statistically significant(P=0.03).Incision enlargement was greatest with Monarch III injector,followed by Royale,and Autosert.Trypan blue concentration into anterior chamber was(log units):GroupI=1.97+0.45,Group II=1.78+0.48,Group III=2.16+0.38;difference not statistically significant(P=0.48).No difference in descemet’s detachment,incision gaping and loss of coaptation between groups at any followup(P>0.05)

Conclusions:

All injectors allowed smooth IOL implantation through a 2.2mm incision;incision enlargement was least using automated injector

Financial Interest:

NONE

Back to previous