Official ESCRS | European Society of Cataract & Refractive Surgeons
London 2014 Registration Visa Letters Programme Satellite Meetings Glaucoma Day 2014 Exhibition Hotel Booking Virtual Exhibition Star Alliance
london escrs

Course handouts are now available
Click here


Come to London

video-icon

WATCH to find out why


Site updates:

Programme Updates. Programme Overview and - Video Symposium on Challenging Cases now available.


Patient satisfaction with a new extended range of vision 1-piece IOL

Search Abstracts by author or title
(results will display both Free Papers & Poster)

Session Details

Session Title: IOL Technology / Accommodative IOLs etc.

Session Date/Time: Saturday 13/09/2014 | 16:00-18:00

Paper Time: 17:18

Venue: Boulevard A

First Author: : B.Cochener FRANCE

Co Author(s): :    E. Multicenter              

Abstract Details

Purpose:

To characterize lens design and performance of the new TECNIS® Symfony Extended Range of Vision 1-Piece Intraocular Lens (IOL), Model ZXR00 (AMO).

Setting:

Brest University Hospital - France

Methods:

Simultaneous vision, or the presence of multiple focused images, in multifocal IOLs leads to halos and glare. Through-focus image quality and point spread function (PSF) simulations were evaluated in order to determine whether a second focus is provided by the new TECNIS® Symfony IOL. Comparisons are made to the 1-month results from a prospective, multicenter clinical study in the EU with bilateral implantations of the TECNIS® Symfony IOL, Model ZXR00, in 150 cataract patients. Key evaluation criteria were defocused visual acuity, subject reports of visual disturbances and patient satisfaction questionnaire responses.

Results:

Simulations of through-focus visual acuity and PSF of the TECNIS® Symfony IOL show a continuous range of vision and a lack of multiple distinct foci. Corresponding comparisons of defocused visual acuity, visual disturbances and resulting patient satisfaction data will be provided from the ongoing clinical study.

Conclusions:

Simulations and optical bench measurements with the new TECNIS® Symfony IOL, Model ZXR00, show a continuous range of vision and PSFs that demonstrate reduced halos resulting in reduced optical/visual symptoms.

Financial Interest:

One or more of the authors... receives consulting fees, retainer, or contract payments from a company producing, developing or supplying the product or procedure presented, One or more of the authors... research is funded, fully or partially, by a company producing, developing or supplying the product or procedure presented

Back to previous