Course handouts are now available
Click here
Come to London
WATCH to find out why
Site updates:
Programme Updates. Programme Overview and - Video Symposium on Challenging Cases now available.
Posters
(results will display both Free Papers & Poster)
A detached DSAEK: looking beyond the obvious
Poster Details
First Author: P.Georgoudis GREECE
Co Author(s): E. Sykakis S. Hamada D. Lake
Abstract Details
Purpose:
We present the investigation and management of a detached DSAEK corneal transplant one week after surgery. It was identified that the DSAEK button was inserted inverted (back-to-front). We describe the technique of surgical inversion and repositioning (including video) and presenting the favourable outcome.
Setting:
Corneoplastic Unit and Eye Bank, Queen Victoria Hospital, East Grinstead, UK
Methods:
A 67 male patient was operated for left cataract and Fuch's endothlelial dystrophy (Combined phacoemulsification & PCIOL implant & DSAEK). He presented a week later with poor vision and the clinical examination demonstrated oedematous cornea and a detached DSAEK graft.
Prior to rebubbling an OCT was performed. It revealed that the DSAEK button had been inadvertently inserted back-to-front.
The patient was operated the same day, where to DSAEK button was inverted to the correct orientation and rebubbled.
Results:
Three weeks later, the patient has a clear thin DSAEK graft, a BCVA of 6/12 and a cell density of 1450 cells/mm2.
Conclusions:
In case of a detached DSAEK, the use of the OCT is very useful in assessing the orientation.
Incorrect orientation does not necessarily lead to graft failure or non reversible damage and with a appropriate surgical management, the result can be very good. FINANCIAL INTEREST: NONE