Official ESCRS | European Society of Cataract & Refractive Surgeons
London 2014 Registration Visa Letters Programme Satellite Meetings Glaucoma Day 2014 Exhibition Hotel Booking Virtual Exhibition Star Alliance
london escrs

Course handouts are now available
Click here


Come to London

video-icon

WATCH to find out why


Site updates:

Programme Updates. Programme Overview and - Video Symposium on Challenging Cases now available.


Posters

Search Abstracts by author or title
(results will display both Free Papers & Poster)

Objective and subjective analysis of incision architecture following the use of two intraocular lens injector systems

Poster Details

First Author: M.Nanavaty UK

Co Author(s):                  

Abstract Details



Purpose:

To assess any changes in incision size and wound architecture when comparing two intraocular lens injector systems

Setting:

Sussex Eye Hospital, Brighton, England

Methods:

A consecutive case series of 40 eyes of 40 patients undergoing standard cataract surgery with IOL implantation. A single surgeon (MAN) performed all surgeries using a 2.2-mm incision and phacoemulsification. All patients received a C-flex Aspheric 970C IOL, using either a RaySert PLUS (Rayner Intraocular Lenses Limited, UK) or the Accuject injector (Medicel AG, Switzerland). The main wound was objectively measured using standardized wound gauges (Duckworth & Kent, UK) at three points during surgery: 1) before insertion of the phacoemulsification probe 2) prior to intraocular lens insertion and 3) post IOL insertion. Leakage of the wound was assessed using 2% fluorescein eye drop (Minims, Bausch+Lomb, Rochester, NY). Following the procedure the surgeon's subjective assessment of the two injector systems was obtained on a four-point Likert scale assessing a number of parameters.

Results:

The study compared several parameters related to the injector system performance: 1) ease of IOL loading into the injector; 2) ease of advancing the IOL into the loading bay and nozzle; 3) the force required to push the IOL through the nozzle; 4) the ease of incision entry, and; 5) the ease in which the IOL exited from the nozzle. These parameters were graded from 1 to 4 with 1 as ‘very difficult'; 2 - ‘difficult'; 3 - ‘easy' and 4 - ‘very easy'.

Conclusions:

Both IOL injector systems provide a safe and effective method of implanting the IOL into the bag during standard cataract surgery. A surgeon's subjective assessment of IOL injector systems should also be taken to into account when determining appropriate manufacturers and will be presented. Further evaluation of a number of injector systems within an NHS setting, would be worthwhile. FINANCIAL INTEREST: One of more of the authors... research is funded, fully or partially, by a company producing, developing or supplying the product or procedure presented