Posters
Outcomes of Lentis Comfort toric implantation in Asian eyes
Poster Details
First Author: T.Ung MALAYSIA
Co Author(s): A. Tey A. Ang
Abstract Details
Purpose:
To evaluate the visual and refractive outcomes of a series of Asian eyes implanted with Lentis Comfort toric IOL following phacoemulsification cataract surgery.
Setting:
International Specialist Eye Centre (ISEC) Penang.
Methods:
Restrospective analysis of all cataract surgeries performed in 2017 with implantation of the Lentis Comfort toric lens implant.
Results:
112 eyes of 89 Asian patients were implanted with the Lentic Comfort toric lens implant in 2017. Pre-oepratively, mean logMAR visual acuity was 0.4 and mean magnitude of corneal astigmatism was 1.5D. Post-operation, at 1 month follow up, mean logMAR visual acuity was 0.15 and mean residual refractive astigmatism was 0.7D. Mean spherical equivalent post-surgery was -0.23D.
Conclusions:
Lentis Comfort toric lens gives good visual outcomes and effectively reduces astigmatism in Asian eyes.
Financial Disclosure:
None