Purpose:
To present the results of implantation of FERRARA ring 210 arc, 250 um thickness, 5 mm optic zone in advanced keratoconus.
Setting:
Medical Center "MAVIT", Warsaw, Poland.
Methods:
FERRARA ring - 210 arc, 250 um thickness, 5 mm optical zone - was implanted in 5 eyes with advanced keratoconus, stage 3/4 according to Amsler-Krumeich scale. In all 5 eyes Vogt's striae were present.
The 360 degrees intracorneal channels were made with femtosecond laser, Visumax, under topic anesthesia.
Preoperative UCVA was from 0,02 to 0,3; preoperative BCVA from 0,3 to 0,5; spherical correction from +0,25D to -7,75D; cylindrical correction from -1,5D to 7,5D.
Maximal anterior surface curvature was from 60,2D to 70,9D; minimal pachymetry from 408um to 483um.
Operations were performed between June 2017 and February 2018.
Results:
In all patients uncorrected and corrected visual acuity was improved. In all patients flattening of anterior curvature was observed.
In all patients Vogt's striae disappeared.
Conclusions:
The femtosecond laser -FERRARA 210 arc intracorneal ring implantation is a very good method to improve vision in eyes with advanced keratoconus.
This method can postpone the necessity of corneal transplantation in advanced keratoconus.
Financial Disclosure:
None