Official ESCRS | European Society of Cataract & Refractive Surgeons
Vienna 2018 Delegate Registration Programme Exhibition Virtual Exhibition Satellites 2018 Survey

 

escrs app advert

Posters

Search Title by author or title

Comparison of intraocular lens power formulas using optical low coherence reflectometry in cataract patients

Poster Details

First Author: G.Kaya TURKEY

Co Author(s):                        

Abstract Details

Purpose:

: To compare the accuracy of various biometric formulas for predicting postoperative refraction determined using an optical low-coherence reflectometry device.

Setting:

Department of Ophthalmology, Kagıthane State Hospital

Methods:

All eyes were divided into three groups according to axial length; short (<22.0 mm), average (22.0–24.5 mm),and long (>24.5 mm) eyes. The mean error and the mean absolute error values (MAE) were calculated for fi ve various IOL formulas (Haigis, Hoffer Q, SRK/T, Holladay 1, and SRK II) were compared.

Results:

The mean absolute errors of 87.5 % of the eyes were within 1 D and of 98.3% were within 2 D. MAE values, in short eyes, for Haigis, Hoffer Q, SRK/T, Holladay 1 and SRK II formulas were 0.35±0.25 D, 0.31±0.27 D, 0.41±0.29 D, 0.43±0.52 D and 0.45±0.31 D, respectively. In average eyes MAE values were 0.51±0.45 D, 0.49±0.43 D, 0.54±0.44 D, 0.50±0.43 D and 0.57±0.45 D, respectively. In long eyes MAE values were 0.51±0.45 D, 0.51±0.43 D, 0.51±0.43 D, 0.49±0.43 D and 0.57±0.54 D, respectively.

Conclusions:

The Haigis, Hoffer Q, SRK/T and Holladay 1 formulas gave more predictable refractive outcome than SRK II formula in all axial length groups.

Financial Disclosure:

None