Official ESCRS | European Society of Cataract & Refractive Surgeons
Vienna 2018 Delegate Registration Programme Exhibition Virtual Exhibition Satellites 2018 Survey

 

escrs app advert

Double-flanged transcleral bag fixation: preliminary report of a new sutureless transscleral fixation of the capsular bag in subluxated cataracts

Search Title by author or title

Session Details

Session Title: IOL Dislocation & Opacification

Session Date/Time: Tuesday 25/09/2018 | 14:00-16:00

Paper Time: 14:36

Venue: Room A3, Podium 1

First Author: : S.Canabrava BRAZIL

Co Author(s): :    L. Bicalho   A. Arancibia   L. Gontijjo   A. Lima           

Abstract Details

Purpose:

Describe a new sutureless technique for fixating the capsular bag in patients with zonular dialysis greater than 120º undergoing cataract surgery. The technique uses a 5.0 polypropylene suture and a Capsular Tension Segment to fixate the subluxated capsular bag in the sclera using a flanged method in the both side of the polypropylene.

Setting:

Santa Casa de Bello Horizonte

Methods:

This is a preliminary report of a consecutive case series that evaluated 12 eyes of 12 patients with zonular dialysis greater than 120º undergoing cataract surgery. The procedure uses a sclerotomy 2.0 mm from the limbus in the same quadrant of the zonular weakness with a 30-gauge needle. It is used as an external guide of the 5.0 polypropylene suture within the sclera. The both sides of the suture are heated and shaped into a flanged. One side is inserted into the sclera and the other side is inserted in the suturing eyelet of the CTS.

Results:

We performed the described technique in 12 patients and it was possible to conclude properly the procedure in 11 eyes. In one of patients, the flanged became thin, which made it impossible to reach the scleral stability intraoperatively. The other 11 eyes did not presented intra or postoperative complications, and besides, during a 6 months follow up it was not detected any intraocular IOL dislocation.

Conclusions:

The absence of sutures, flaps and glue makes it faster to perform, induces less trauma and presents a less steep learning curve. It also avoids complications associated with suture degradation and subsequent IOL dislocation over time. However, as a new technique, it is necessary further studies with more patients and longer follow-up.

Financial Disclosure:

-

Back to previous