Customised toric intraocular lens for very high corneal astigmatism
Session Details
Session Title: New IOLs: Material & Preload IOL
Session Date/Time: Monday 24/09/2018 | 08:00-10:30
Paper Time: 09:06
Venue: Room A3, Podium 2
First Author: : V.MITTAL INDIA
Co Author(s): : P. Narang R. Mittal
Abstract Details
Purpose:
To evaluate the efficacy of ‘Smart Toric plus’ intraocular lens (IOL) implantation in patients with high astigmatism and cataract after penetrating keratoplasty or keratoconus
Setting:
LJ Eye Institute, Ambala
Methods:
8 eyes of 8 patients with cataract and high regular astigmatism underwent Phacoemulsification and implantation of foldable hydrophilic acrylic IOL (ULTIMA Smart toric plus). Main outcome measures: uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) in logMAR and manifest refraction.
Results:
Mean astigmatism was 11.8D( Range 8.0- 15.34D). The mean follow- up duration was 13.5 months. All 8 eyes had significant improvement in post- operative UDVA (logMAR,1.019±0.612 to 0.568±0.305; P= 0.0001) and CDVA(logMAR,0.885±0.592 to 0.197±0.102; P= 0.0001). The degree of astigmatism was also reduced significantly. Redialling (done in three eyes) was safe and also yielded good outcomes.
Conclusions:
Customised Toric IOL appears to be a good option for patients with high astigmatism.
Financial Disclosure:
-