Scharioth macula lens for AMD: quality of life study

Search Title by author or title

Session Details

Session Title: New IOLs: Material & Preload IOL

Session Date/Time: Monday 24/09/2018 | 08:00-10:30

Paper Time: 08:12

Venue: Room A3, Podium 2

First Author: : N.Nielsen DENMARK

Co Author(s): :    A. Helgesen   G. Muus                 

Abstract Details

Purpose:

To register and analyse changes in vision and Quality Of Life in patients with AMD after implantation of the Scharioth Macula Lens (SML).

Setting:

Eye Hospital Denmark - Charlottenlund, Denmark

Methods:

Consecutive non-randomized 6 months follow-up study of Quality Of Life by VFQ-25 questionary and vision in 25 patients with AMD.

Results:

Far vision was unchanged. Near vision measured by the Radner test improved from Radner 8.3 to Radner 5.8 (P<0.01). Quality Of Life assessed by VFQ-25 questionary showed a significant improvement from VFQ-score 868.5 to VFQ-score 1106.5 (P<0.01). Especially in the group with previous legal blindness compared with the group with partial sight.

Conclusions:

Near vision improved according to the preoperative predictable measurements, whereas far vision was unchanged. Quality Of Life surprisingly improved in the group with legal blindness i.e a bettering of daily activities.