Multicenter visual outcomes evaluation of a novel trifocal presbyopia-correcting intraocular lens: 12 month postoperative results

Search Title by author or title

Session Details

Session Title: Multifocal IOLs

Session Date/Time: Sunday 23/09/2018 | 16:30-18:00

Paper Time: 16:36

Venue: Room A3, Podium 1

First Author: : T.Kohnen GERMANY

Co Author(s): :    A. Martinez                    

Abstract Details

Purpose:

A prospective, single arm, non-randomized, multi-center study (17 sites) was conducted involving the bilateral implantation of AcrySof IQ PanOptix Presbyopia Correcting IOL in 151 subjects. Binocular uncorrected distance visual acuity (UDVA) (4m), binocular distance corrected intermediate visual acuity (BDCIVA) (60cm & 80cm), binocular uncorrected near visual acuity (UNVA) (40cm) and binocular defocus curves were evaluated under photopic lighting conditions.

Setting:

Department of Ophthalmology, Goethe University, Frankfurt am Main, Germany

Methods:

A prospective, single arm, non-randomized, multi-center study (17 sites) was conducted involving the bilateral implantation of AcrySof IQ PanOptix Presbyopia Correcting IOL in 151 subjects. Binocular uncorrected distance VA (4m), binocular distance corrected intermediate VA (60cm & 80cm), binocular uncorrected near VA (40cm) and binocular defocus curves were evaluated under photopic lighting conditions.

Results:

145 subjects (38% male: 62% female, mean age: 68.9 ± 9.3 years) implanted with the AcrySof IQ PanOptix IOL bilaterally were followed for 1 year. At 1 year post-op, the mean ± SD (logMAR) UDVA was 0.02 ± 0.11; mean BDCIVA was 0.04 ± 0.12 (60cm) and 0.08 ± 0.14 (80cm). Mean ± SD UNVA was 0.07 ± 0.11. At 6-months follow up, the mean defocus curve VA from 0.00D to -3.00D ranged from 0.1 to 0.0 logMAR. Average VA at distance (0.00D), intermediate (-1.50D) and near (-2.50D) was 0.0 ± 0.1D, 0.0 ± 0.1D and 0.1 ± 0.1D.

Conclusions:

The results from this study show very good visual performance (VA better or equal to 20/25) of the AcrySof IQ PanOptix IOL in both uncorrected and corrected conditions across the whole range of distances and defocus.

Financial Disclosure:

... receives consulting fees, retainer, or contract payments from a company producing, developing or supplying the product or procedure presented