Visual outcomes with PanOptix Toric implantation planned using Verion Vision Planner 3.1

Poster Details

First Author: A.Dmitriew POLAND

Co Author(s):    W. Adamski   A. Chomicka                 

Abstract Details

Purpose:

To determine the visual outcomes of trifocal, toric, hydrophobic IOL, the Alcon Acrysof IQ PanOptix Toric.

Setting:

St. Adalbert Hospital/Szpital sw. Wojciecha Poznan, Poland

Methods:

A retrospective single-center study. The study included patients with cataract or qualified for a refractive lens exchange (RLE) implanted with Alcon Acrysof IQ PanOptix Toric. The surgery was planned using Alcon Verion Vision Planner 3.1. 15 eyes of 10 subjects were operated by 1 surgeon, 5 patients had the lens implanted binocularly. Uncorrected and corrected distance, intermediate and near visual acuity as well as refractive errors were measured.

Results:

Eleven eyes had hyperopia with corneal astigmatism, 4 eyes were emmetropic before the surgery.  All patients benefited, to differing extents, from gained distance, intermediate and near visual acuity quality, however residual refractive error (myopic shift) appeared in 1 patient, that underwent prior laser surface ablation, requiring additional laser correction.

Conclusions:

Performance of Alcon Acrysof PanOptix Toric gives promising visual outcomes. Alcon Verion Vision Planner 3.1 gives satisfactory accuracy in prediction of residual refractive error.

Financial Disclosure:

... travel has been funded, fully or partially, by a competing company

Back to Poster listing