IOLs for AMD patients: EyeMax mono – two years' follow-up
Session Details
Session Title: Presented Poster Session: New & Interesting II
Venue: Poster Village: Pod 3
First Author: : N.Nielsen DENMARK
Co Author(s): : A. Helgesen G. Muus
Abstract Details
Purpose:
To register and analyze changes in vision in patients with AMD after implantation of the EyeMax mono IOL.
Setting:
Eye Hospital Denmark - Charlottenlund, Denmark
Methods:
Consecutive non-randomized 2 years follow-up study of vision in 30 eyes of 21 patients with AMD.
Results:
The vision was measured by ETDRS. CDVA improved from 0,21 decimal to 0,38 decimal at 6 months (P<0.01). At 2 years follow-up CDVA was 0,35 decimal.
The patients in the group with partial sight had a higher degree of improvement compared with the legal blind group. These results remained unchanged after 2 years.
Conclusions:
The primary selection criteria for inclusion to implant EyeMax mono were reliable after 2 years. The visual performance in daily life activities was stable.
Financial Disclosure:
... receives non-monetary benefits from a company producing, developing or supplying the product or procedure presented