Punchorhexis in white intumescent cataract
Session Details
Session Title: Cataract Surgery: Special Cases
Session Date/Time: Tuesday 17/09/2019 | 08:30-10:30
Paper Time: 10:12
Venue: Free Paper Forum: Podium 2
First Author: : M.Rajan INDIA
Co Author(s): : S. Moan
Abstract Details
Purpose:
To do a perfect rhexis in white intumescent cataract.
Setting:
Rajan Eye Care Hospital Pvt Ltd, Chennai.
Methods:
250 eyes of 250 patients with white intumescent cataract were taken up for this study. Trephine blue was used to stain the anterior capsule. The punchorhexis was done using a straight 15 degree phaco tip bevel down using 40% phaco power, 350-400mm Hg vacuum on the stellaris phaco machine. Once a punch was made the rhexis was completed either with the phaco needle itself (phaco rhexis) or with uttrata forceps.
Results:
In all eyes except one eye the punchorhexis was successful.
Conclusions:
Punchorhexis is an effective method of achieving good rhexis in white intumescent cataract there by preventing argentina flag sign.
Financial Disclosure:
None