Registration Programme Overview Exhibition Virtual Exhibition Satellite Programme Hotel Information VISA Letter Application

 

Pinhole intraocular lens to correct presbyopia and astigmatism: 3 year follow-up

Search Abstracts by author or title
(results will display both Free Papers & Poster)

Session Details

Session Title: Cataract
Session Date/Time: Saturday 16/02/2019 | 08:30-11:00
Paper Time: 09:36
Venue: Hall Trianti

First Author: B.Kusa ITALY
Co Author(s): M. Piovella                 

Abstract Details

Purpose:

To demonstrate visual performance of the IC-8 small aperture IOL (AcuFocus, Irvine, CA) implanted in patients in whom a cataractous lens has been removed.

Setting:

C.M.A. Centro Microchirurgia Ambulatoriale Via Donizetti 24 Monza Italy

Methods:

21 Eyes with cataract, corneal astigmatism ≤ 1.25,had IC-8 IOL implantation in the non dominant eye and a monofocal IOL in the dominant eye.Postoperatively,visual and refractive parameters were measured:distance(4m)near(40cm)and intermediate(80 cm)visual acuity, corneal topography and Acutarget analysis, contrast sensitivity and defocus curve. Follow-up examinations were performed up to 3 years

Results:

At 3 years in the IC-8 eye,UDVA is 20/20.5,UIVA is 20/19 at 80cm and 67 cm and UNVA is 20/20.5.In the monofocal eye,UDVA is 20/19,UIVA is 20/23 at 80cm 20/25.7 at 67cm and UNVA is 20/50.Binocular UDVA is 20/18,UIVA is 20/18.3(80 cm and 67cm)and UNVA is 20/20.5

Conclusions:

Pinhole technology in the non dominant eye mixed with monofocal IOL in the dominant eye provides good far,intermediate and near vision. Pinhole effect normally corrects up to two diopters of corneal astigmatism and overcome toric IOL management within this range

Financial Disclosure:

... receives consulting fees, retainer, or contract payments from a company producing, developing or supplying the product or procedure presented, ... travel has been funded, fully or partially, by a company producing, developing or supplying the product or procedure presented