Session Title: Phakic IOL Implantation II
Session Date/Time: Wednesday 09/10/2013 | 08:00-10:30
Paper Time: 09:28
Venue: E104-105 (First Floor)
First Author: : A.Marinho PORTUGAL
Co Author(s): :
Purpose:
To evaluate endothelial cell loss 3 years after implantation of Acrysof Cachet phakic IOL
Setting:
Hospital Arrabida
Methods:
121 myopic eyes were implanted with Acrysof Cachet phakic IOL. Central endothelial cell count was evaluated before surgery, 3 months after surgery and yearly afterwards. Endothelial cell loss was correlated with rotation of the IOL, depth of anterior chamber and compression of the IOL.
Results:
The overall results showed an endothelial cell loss of 4% at 3 years follow-up. No correlation was found between endothelial cell loss and rotation of the IOL ,anterior chamber depth or compression of the IOL.
Conclusions:
At 3 years follow-up Acrysof Cachet is safe for the endothelium as long as the correct inclusion criteria are followed
Financial Interest:
... receives consulting fees, retainer, or contract payments from a company producing, developing or supplying the product or procedure presented