Session Title: Imaging II
Session Date/Time: Monday 07/10/2013 | 16:30-18:00
Paper Time: 16:42
Venue: Main Lecture Hall (Ground Floor)
First Author: : G.Baikoff FRANCE
Co Author(s): : E. FUENTES
Purpose:
The high resolution OCT can measure the corneal epithelium with a ± 2µm precision. Several authors have described epithelium disorders in keratoconus patients with an importance for screening "forme fruste" keratoconus. The aim was to establish a relationship between the epithelial thickness and the anatomy of the cone.
Setting:
Clinic Monticelli, 88 rue du Cdt Rolland, 13008 Marseille, France
Methods:
100 frank keratoconus were studied. An isolated analysis is carried out on a few "forme fruste" keratoconus. The OCT scanning zone is 6mm. The parameters retained were: minimum corneal pachymetry, minimum epithelial thickness, maximum epithelial thickness, the difference between epithelial thicknesses (? mini max), and superior - inferior variations (? S I), the steepest keratometry (KS), mean keratometry (KM)
Results:
It appears that the epithelium thickness, the differences of epithelium thicknesses (? mini max), (? S I) are closely linked to the minimum corneal thickness, the steepest keratometry and the mean keratometry. However, we are not sure of a significant relationship for the "forme fruste" keratoconus
Conclusions:
Keratoconus severity (thinning and steepening of the cornea) is closely linked to the epithelial variations: minimum thickness, differences of thicknesses (min max) superior - inferior variations