Session Title: Presbyopia Correction
Session Date/Time: Monday 07/10/2013 | 16:30-18:15
Paper Time: 17:48
Venue: Emerald (First Floor)
First Author: : S.Kostenev RUSSIA
Co Author(s): : V. Chernykh
Purpose:
To research shape, thickness and biomechanical properties of the cornea after INTRACOR.
Setting:
S.N. Fyodorov Eye Microsurgery Complex, Novosibirsk Branch
Methods:
Clinical trial is based on results of measurement cornea in 10 patients (11 eyes) after operation. The operation was performed with the femtosecond laser FEMTEC (Technolas-Perfect Vision). Pre- and postoperative complete ophthalmic examination including uncorrected and best spectacle corrected visual acuity, corneal topography Zyoptix (Bausch&Lomb), OCT (Optovue) was done.
Results:
After INTRACOR the power of the center cornea (3,0 mm) has increased up to 2,0 ± 0,25 D. We didn"t observe considerable changes of biomechanical properties of a cornea after operation. One day, one week, one and three months postoperatively the exams revealed a stable uncorrected near visual acuity with a mean gain of 5 lines of near visual acuity and no change in distance visual acuity.
Conclusions:
The new operation (INTRACOR) treatment of presbyopia shows very promising results in the correction of presbyopia.
Financial Interest:
NONE