Experience with refractive hydrophilic acrylic RAYNER multifocal IOLs: mix and match

Poster Details

First Author: Z.Mazhry PAKISTAN

Co Author(s):    W. Kadri              

Abstract Details



Purpose:

To evaluate the Refractive Hydrophilic Acrylic multifocal RAYNER IOLs in terms of safety and post op results stressing on improvement in quality of vision after cataract surgery and compatibility with other eye having its own crystalline lens, monofocal IOL or multifocal IOL.

Setting:

Eye Department Central Park Medical College &WAPDA Teaching Hospital Complex 210 Feroz Pur Road Lahore Pakistan.

Methods:

Early results of study of 25 eyes implanted with Refractive Hydrophylic Acrylic multifocal IOLs from October 2010 to Dec 2011.

Results:

All 25 eyes had smooth Phaco and intra bag injection of IOLs with their recommended IOL Insertion System. Only three patients had bilateral implantation. All the IOLs were excellently centered intra-operatively and remained so in post op follow up. We had two unhappy patients, one because of residual astigmatism of -1.5D and the other one with no obvious reason. Both these patients are comfortable with both eyes open. We have planned LASEK for the first patient and the second one settled down 3 months post with a little delayed neuroadaptation. Rests of the patients were satisfied and happy with their own respective combinations.

Conclusions:

Mixing and matching of Refractive Hydrophilic Acrylic RAYNER multifocal IOLs is possible in motivated well counseled patients. Refractive multifocal IOL Rayner 630F appears superior in our experience regarding centration and perfection in far and near vision. FINANCIAL DISCLOSURE?: ... travel has been funded, fully or partially, by a competing company