First Author: K.Okasha PALESTINE
Co Author(s):
Purpose:
To analyze the results of refractive lens exchange with primary piggyback multifocal and high power intraocular lens implantation for high hypermetropia
Setting:
International Eye Center-Gaza-Palestine
Methods:
A case study of 20 years old female patient with bilateral extreme hyperopia with UCVA 3/60 and BCVA 6/18 with +12 sphere of refraction . Bilateral sequential clear lens exchange with primary +42 D aspherical lens (C-flex® Aspheric- Rayner) which was implanted in the bag and multifocal (Rayner Sulcoflex® supplementary IOL) was implanted in the sulcus.
Results:
The postoperative uncorrected visual acuity was 6/18 in both eyes and , uncorrected near acuity of J5 in both eyes at 6 months follow up . Both eyes were within ±0.50 D of the emetropia
Conclusions:
Refractive lens exchange with primary piggyback multifocal and high power intraocular lens implantation for high hypermetropia is safe, predictable, and effective FINANCIAL DISCLOSURE?: No
Please wait while information is loading.