Purpose:

This is a retrospective study of 40 eyes where we implanted a bitoric, aspheric (aberration neutral) and monofocal IOL mono- and binocular to correct corneal astigmatism. Up to 4 years postoperatively examinations were done for evaluation of visual acuity, refractive error especially cylindric refraction and high order aberrations.

Setting:

Breyer Eye Surgery, Dusseldorf, Germany

Methods:

We implanted a bitoric IOL after CO-MICS through a 1.5 – 1.8 mm incision in about 40 eyes. Subjective Refraction, Pentacam, Aberrometry and IOL orientation were examined and analyzed.

Results:

IOL with a cylindric power between 0.5 and 8.5 diopters were implanted. The mean value of the postoperative spherical equivalent was -0.05 diopters and of the postoperative cylinder -0.35 diopters. No IOL re-orientation was necessary.

Conclusions:

Due to its high predictability and rotation stability CO-MICS and the implantation of the bitoric IOL became a routine procedure in correcting corneal astigmatism in our cataract surgery. FINANCIAL DISCLOSURE?: ... receives consulting fees, retainer, or contract payments from a competing company