Official ESCRS | European Society of Cataract & Refractive Surgeons
Copenhagen 2016 Registration Programme Exhibitor Information Virtual Exhibition Satellite Meetings Glaucoma Day 2016 Hotel Star Alliance
title

10 - 14 Sept. 2016, Bella Center, Copenhagen, Denmark

This Meeting has been awarded 27 CME credits

 

escrs app advert yo advert

Posters

Search Title by author or title

To evaluate the rotational stability of Visian toric ICL using ray tracing technology

Poster Details

First Author: S. Goel INDIA

Co Author(s):    S. Mukherjee                    

Abstract Details

Purpose:

To assesss axis alignment and stability of the toric implantable collamer lenses ticl staar sugical company

Setting:

Anand Hospital & Eye Centre, Jaipur

Methods:

45 eyes of 26 patients received ticl for treatment of myopic astigmatism mrse and manifets refractive cylinder were measured pre and postop the axis allignment was mesured using the ray tracing technology of I Tracey (HOYA)

Results:

Both postoperative uncorrected visual acuity (UCVA) and best spectacle-corrected visual acuity (BCVA) were significantly improved when compared with preoperative values (p<0.05).

Conclusions:

There was no statistically significant rotation between early follow-up (1 month and 3 months) and final follow-up (p=0.215, p=0.492, respectively). Three eyes exhibited ICL rotation of 5 degrees and the remaining eyes (96.7%) had ICL rotation of less than 5 degrees.

Financial Disclosure:

NONE