Official ESCRS | European Society of Cataract & Refractive Surgeons
Copenhagen 2016 Registration Programme Exhibitor Information Virtual Exhibition Satellite Meetings Glaucoma Day 2016 Hotel Star Alliance
title

10 - 14 Sept. 2016, Bella Center, Copenhagen, Denmark

This Meeting has been awarded 27 CME credits

 

escrs app advert yo advert

Posters

Search Title by author or title

Refractive and diffractive contribution of linear chromatic aberration (LCA) on depth-of-focus with trifocal intraocular lenses (IOLs)

Poster Details

First Author: J. Loicq BELGIUM

Co Author(s):    D. Gatinel                    

Abstract Details

Purpose:

To investigate the refractive and diffractive contribution of LCA on depth of focus extension of trifocal IOLs in polychromatic light conditions

Setting:

University of Liège, Belgium; Fondation Ophtalmologique A. de Rothschild, Paris

Methods:

The LCAs associated with the three focal points of hydrophobic and hydrophilic diffractive FineVision trifocal IOLs (PhysIOL SA, Liège, Belgium), were simulated in an Arizona eye model and experimentally measured on an optical bench at 480, 546 and 650 nm. The effect of Abbe number and aperture on different IOL materials was also evaluated. Based on wavelength–dependent MTF through-focus curves and PSF properties, polychromatic behavior of the trifocal IOLs was assessed under mesopic and photopic conditions.

Results:

LCA amplitude and sign were different for each of the trifocal IOL focal points. The diffractive LCA for near and intermediate was independent of IOL material (GFree versus hydrophilic acrylic, 26%), while far vision LCA appeared to be controlled by the material Abbe number. Under polychromatic conditions, the LCA contributed to depth of focus extension with different types of lens material, providing maximal visual acuity under white light conditions at all distances.

Conclusions:

Diffractive trifocal IOLs show chromatic aberrations with an increase in depth of focus under polychromatic light. This effect likely contributes to the extended range of vision.

Financial Disclosure:

One or more of the authors gains financially from product or procedure presented, One or more of the authors research is funded, fully or partially, by a company producing, developing or supplying the product or procedure presented, One or more of the authors receives consulting fees, retainer, or contract payments from a company producing, developing or supplying the product or procedure presented

Back to Poster listing