Official ESCRS | European Society of Cataract & Refractive Surgeons
Copenhagen 2016 Registration Programme Exhibitor Information Virtual Exhibition Satellite Meetings Glaucoma Day 2016 Hotel Star Alliance
title

10 - 14 Sept. 2016, Bella Center, Copenhagen, Denmark

This Meeting has been awarded 27 CME credits

 

escrs app advert yo advert

Posters

Search Title by author or title

Nine month follow-up on enhancement surgery following primary PrecisightTM, multicomponent IOL cataract surgery

Poster Details

First Author: F. Sanchez Leon MEXICO

Co Author(s):                        

Abstract Details

Purpose:

To analyze nine month followup results on enhancement surgery following primary PrecisightTM, multicomponent IOL cataract surgery

Setting:

Novavision Laser Center, Mexico City

Methods:

Two patients underwent uneventful cataract surgery thirteen months prior to this study. The multicomponent PrecisightTM lens was implanted in both patients with resulting average UCVA 20/40 and with an average -1.25D residual refraction, at 4 months postoperatively. Under topical anesthesia, the original 2.2mm cataract wound was re-entered. Grasping forceps were used to grasp the front lens after it was freed up from the surface of the base lens. The original front lens was removed and a new front lens was injected and reassembled with the original base lens. This exchange procedure took less than 3 minutes.

Results:

Nine months postoperatively, the average residual refraction was +0.36D and UCVA 20/25. Both patients were extremely satisfied with the visual results. This represents the very first attempt of this exchange procedure. It is expected the refinement of the optical and physical parameters of the system will further enhance accuracy. A video demonstration of the exchange procedure will be shown.

Conclusions:

The PrecisightTM multicomponent IOL was developed to offer patients a customized IOL prescription at the time of primary cataract surgery, as well as giving the patients and surgeon an easy way to correct or adjust any postoperative refractive surprise at any time postoperatively. This paper demonstrates the nine month followup for this 5 minute enhancement procedure which was beneficial for the patient and surgically, a very simple procedure for the surgeon. Further technical refinements should further increase its accuracy.

Financial Disclosure:

NONE

Back to Poster listing