Meeting Highlights Information Registration Visa Letter Application Programme Overview Exhibition Virtual Exhibition Hotels Exhibition Virtual Exhibition Satellite Programme


Posters

Search Abstracts by author or title
(results will display both Free Papers & Poster)

Anterior segment characteristics in normal and keratoconus eyes evaluated with a combined Scheimpflug/Placido corneal imaging device

Poster Details


First Author: N.Nassiri IRAN

Co Author(s): K. Sheibani   S. Kavousnezhad                 

Abstract Details

Purpose:

The aim of this study was to evaluate the effect of CXL on corneal topographic and uncorrected distance visual acuity (UDVA) by Oculus Pentacam in the 15-30-year-old population.

Setting:

Iran University of Medical Sciences, Tehran, Iran.

Methods:

In this descriptive-analytic study, we enrolled 38 eyes of 27 patients suffering from progressive keratoconus who were candidates for CXL. UDVA and the anterior and posterior corneal curvatures assessed prior to and 12 months after CXL.

Results:

One year after the CXL, mean UDVA significantly improved 0.1 ± 0.25 logarithm of the minimal angle of resolution (p = 0.012). Changes for steep keratometry values, flat keratometry, and mean keratometry on the anterior corneal surface were statistically significant (all p < 0.005). However, the difference observed in maximum keratometry and astigmatism was not significant (p = 0.421 and p = 0.745, respectively). After 12 months, all four keratometry values on the posterior corneal surface had increased significantly (p < 0.005), while no significant change observed in astigmatism (p = 0.303).

Conclusions:

Corneal collagen crosslinking has been revealed as an effective and minimally invasive intervention for the treatment of progressive keratoconus that can improve UDVA.

Financial Disclosure:

None

Back to Poster listing