Outcomes of 46 eyes with AcrySof IQ toric intraocular lens of SN6AT9 subtype following routine cataract surgery in the National Health Service, United Kingdom

Poster Details

First Author: S.Selvam UK

Co Author(s):    M. Arunakirinathan   S. Khan                 

Abstract Details

Purpose:

To report post-operative uncorrected distance visual acuity (UDVA), spherical equivalent (SE) and residual astigmatism using a toric intraocular lens (IOL) Acrysof IQ SN6AT9 subtype (Alcon Laboratories, Inc).

Setting:

Cataract Service, Moorfields Eye Hospital, NHS Foundation Trust, London, United Kingdom (UK).

Methods:

Retrospective analysis of 47 eyes that underwent insertion of Acrysof IQ toric IOL, SN6AT9 subtype (2013-16).

Results:

Mean post-operative UDVA (Snellen acuity) by IOL subtype T9 = 6/13. Mean SE achieved was -0.12D (range -2.0D to �.9D) and mean residual manifest cylinder was -1.65D (range -5.5D to �.0D).

Conclusions:

The SN6AT9 subtype corrects 4.11D of toricity at the corneal plane. Patients were appropriately counselled pre-operatively to expect residual astigmatism that would require correction post-operatively.

Financial Disclosure:

receives non-monetary benefits from a company producing, developing or supplying the product or procedure presented.