Posters
Clinical outcomes of binocular implantation of trifocal diffractive intraocular lens
Poster Details
First Author: E.Sunay TURKEY
Co Author(s): F. Helvacioglu O. Kavalcioglu S. Kaya Unsal A. Akyurt T. Akin
Abstract Details
Purpose:
To evaluate the visual and refractive outcomes, and patient satisfaction after bilateral diffractive trifocal intraocular lens (IOL) implantation.
Setting:
VeniVidi Eye Hospital - Istanbul
Methods:
This prospective nonrandomized study included consecutive patients undergone cataract surgery with bilateral implantation of diffractive trifocal IOL (Alcon AcrySof�Â�®�Â� IQ PanOptix).�Â� Distant, intermediate, and near visual outcomes were evaluated as well as the refractive outcomes 3 months after the surgery.�Â� Patient satisfaction, was also evaluated.
Results:
Eighty eyes of 40 patients were included.�Â� 90% of eyes showed spherical equivalence within �Â�±0.50 diopters 3 months after the surgery.�Â� All patients had �Â� binocular uncorrected distant visual acuity (UCDVA OU) of 0.00 LogMAR or better and binocular uncorrected intermediate visual acuity (UCIVA OU) of 0.10 LogMAR or better, 3 months after the surgery.�Â� Furthermore, 90% of patients achieved binocular uncorrected near visual acuity (UCNVA OU) of 0.10 LogMAR or better.
Conclusions:
Trifocal diffractive IOL implantation seems to provide an effective restoration of visual function for far, intermediate and near distances, providing high levels of visual quality and patient satisfaction.
Financial Disclosure:
NONE