Posters
(results will display both Free Papers & Poster)
Customized CXL
Poster Details
First Author: T.Seiler SWITZERLAND
Co Author(s): I. Fischinger T. Koller T. Seiler
Abstract Details
Purpose:
To investigate safety and efficacy of tomography-customized corneal crosslinking and to prove hypothesis of focal weakening in primary corneal ectasia.
Setting:
Institut für Refraktive und Ophthalmo-Chirurgie (IROC), Zurich, Switzerland
Methods:
In a prospective study, 22 eyes of 22 patients were treated with customized crosslinking for halting the progression of keratectasia and followed for 12 months. Standard 0.1% riboflavin in 12% dextran was applied for 30 min. The irradiation-profiles were centred on the maximum posterior float with energy fluencies of 10mW/cm². The total energy applied to the corneas had a maximum of 15J/cm². BSCVA, Scheimpflug imaging, topography, endothelial cell count, AS-OCT and slit lamp examination were collected as pre- and postoperative parameters.
Results:
BSCVA increased by -0.08 ± 0.16logMAR (p=0.17). No eye had a loss of more than 1 Snellen line. Kmax decreased by -0.80 ± 1.08D (p=0.11). Corneal pachymetry decreased by -9 ± 11µm (p=0.05), the endothelial cell count did not change significantly (p=0.44). Average epithelium healing time was 2.63 ± 0.48. One eye showed sterile infiltrates, no other complications occurred
Conclusions:
Customized corneal crosslinking is a promising approach for halting the progression of keratectasia. Due to the smaller abrasion zone necessary, customized CXL presents a less invasive procedure for the patient. These prelimited results in terms of safety and efficacy are comparable to conventional crosslinking. Larger study groups are needed to prove safety and validate the efficacy.
Financial Disclosure:
NONE