Posters
(results will display both Free Papers & Poster)
Analysis of multifocal IOL refractive outcomes with intraoperative aberrometry and streaming refractive data
Poster Details
First Author: J.Brinton USA
Co Author(s): J. Hunter
Abstract Details
Purpose: 
Compare refractive outcomes after multifocal IOL implantation with intraoperative aberrometry with and without streaming refractive data (ORA with VerifEye and ORA, respectively). 
Setting: 
 Multi-center data collected from global database of ophthalmologists using ORA. 
Methods: 
 Data from multiple sites were compared, including 1,971 cases with standard intraoperative aberrometry and 1,267 cases using aberrometry with streaming refractive data. 
Results: 
 The mean absolute value of prediction error was 0.3 ± 0.27 D for standard aberrometry and 0.28 ± 0.24 D for aberrometry with streaming data (p ˂ 0.03). The percentage of eyes ≤ 0.5 D was 83% in the standard aberrometry group vs. 85% in the streaming data group. 
Conclusions: 
 Intraoperative aberrometry with streaming refractive data yielded better refractive results than standard aberrometry. 
Financial Disclosure: 
 NONE
 
     
 