Official ESCRS | European Society of Cataract & Refractive Surgeons
Barcelona 2015 Programme Registration Glaucoma Day 2015 Exhibition Virtual Exhibition Satellite Meetings Hotel Booking Star Alliance
ISTANBUL escrs









Take a look inside the London 2014 Congress

video-icon

Then register to join us
in Barcelona!





Long-term postoperative results following implantation of a single trabecular bypass stent during small incision cataract surgery in patients with glaucoma or ocular hypertension

Search Abstracts by author or title
(results will display both Free Papers & Poster)

Session Details

Session Title: Combined Cataract Surgery Techniques. Surgical Devices

Session Date/Time: Saturday 05/09/2015 | 08:30-10:30

Paper Time: 08:48

Venue: Main Auditorium

First Author: : T.Neuhann GERMANY

Co Author(s): :    R. Neuhann                    

Abstract Details

Purpose:

To assess long-term efficacy and safety after implanting a single iStent® during small incision cataract surgery in subjects with primary open angle glaucoma (POAG), pseudoexfoliation glaucoma, ocular hypertension and secondary, post-traumatic glaucoma. The iStent can reestablish physiologic outflow and reduce intraocular pressure (IOP) via creation of a direct access to Schlemm's canal.

Setting:

AaM Augenklinik Marienplatz Munich, Germany

Methods:

Following phacoemulsification and intraocular lens (IOL) implantation through a temporal, limbal incision, a single iStent was implanted through the same incision in a consecutive series of 62 eyes (43 subjects). With long-term follow-up through 3 years completed in 41 subjects, continued postoperative follow-up for the entire set of cases is ongoing. Intraocular pressure (IOP), topical ocular hypotensive medication use, best corrected visual acuity (BCVA), cup to disc (CD) ratio, complications and adverse event assessment were included in the preoperative and postoperative measurements.

Results:

Sixty-three percent (n=39) of eyes had POAG, and 40% (n=25) had prior laser or incisional glaucoma surgeries. Mean preoperative IOP was 24.1 ± 6.9 mmHg on 1.9 ± 0.9 medications. Sixty-six percent (n=41) were taking 2 or more medications preoperatively. Mean IOP reduced to 14.8 ± 4.2 mmHg, 14.5 ± 2.2 mmHg and 14.9 ± 2.3 mmHg at postoperative years 1, 2 and 3, with reduction in medications to 0.3 ± 0.6, 0.3 ± 0.4, and 0.3 ± 0.5. No operative or postoperative stent-related adverse events occurred. Five patients required secondary glaucoma surgeries for IOP control.

Conclusions:

In our series, outcomes through 3 years after use of iStent during cataract surgery showed long-term, stable reduction in IOP and medications, with no intra- or postoperative complications typically seen with conventional glaucoma surgeries. We have found the iStent to be a safe and effective treatment option through 3 years postoperative in patients with ocular hypertension or open-angle glaucoma. Longer term data past 36 months will be presented.

Financial Interest:

NONE

Back to previous