Epithelial remodeling comparison following myopic SMILE vs myopic LASIK
(results will display both Free Papers & Poster)
Session Details
Session Title: Interactive Free Paper Session: Femtosecond Small Lenticule Extraction I
Session Date/Time: Monday 07/09/2015 | 09:00-11:00
Paper Time: 09:24
Venue: Room 19
First Author: : G.Pamel USA
Co Author(s): : A. Kanellopoulos G. Asimellis, PhD
Abstract Details
Purpose:
To comparatively evaluate epithelial remodeling differences between myopic correction performed with Small Incision Lenticule Extraction (SMILE) and Femto-second LASIK.
Setting:
LaserVision.gr Clinical and Research Eye Institute, Athens, Greece
Methods:
Fourier-domain OCT (Avanti, Optovue, Fremont, CA) epithelial imaging was employed to instigate changes in epithelial thickness (Center over the 2 mm-diameter pupil center disk; Mid-peripherally between the 2 to 5 mm zones). Changes were observed six months postoperatively, in comparison to the pre-operative baseline. 50 myopic cases were investigated. Group-A involved 25 cases in which the SMILE procedure was applied (Visumax, Carl Zeiss Meditec, Jena Germany), while Group-B 25 cases in which the LASIK procedure was applied (FS200 femtosecond and EX500 excimer lasers, Alcon, Ft. Worth, TX).
Results:
In group A (SMILE) there was a central epithelial thickness increase of +1.86μm (p=0.0035) centrally, and mid-peripherally +4.01 μm (p<0.001).
In group B (LASIK) there was a central epithelial thickness increase of +1.98μm (p=0.0022) centrally and mid-peripherally +4.58 μm (p<0.001).
When comparing subgroups of matched myopic correction, significant differences between the two groups were noted. For high myopia (more than 6.00 D), in group A (SMILE) the mid-periphery epithelial thickness increase was +4.39μm and +4.75μm for the -7.00 to -8.00D and -8.00 to -9.00D subgroups, respectively. In group B (LASIK), the corresponding epithelial thickness increase was +7.07μm and +9.80μm, respectively.
Conclusions:
Myopic SMILE and femto-second LASIK appear to result in comparable epithelial thickness remodeling for small myopia corrections; however there is a noted difference in high myopia corrections.
Financial Interest:
One of the authors travel has been funded, fully or partially, by a company producing, developing or supplying the product or procedure presented