Posters

Search Title by author or title

Comparison of the calculation according to 7 formulas in patients who received target refraction after implantation of a trifocal IOL

Poster Details

First Author: S.Sergey RUSSIA

Co Author(s):    O. Kirillova   E. Boiko                 

Abstract Details

Purpose:

To evaluate the calculation accuracy of the trifocal IOL according to 7 formulas in patients who received emmetropic refraction and high visual acuity.

Setting:

S. Fyodorov Eye Microsurgery Federal State Institution, Saint-Petersburg, Russia.

Methods:

The study included 41 patients (51 eyes) who received emmetropic refraction and high visual acuity (Distance Visual Acuity was not lower than 0.8 (LogMar 0.1), Near Visual Acuity not less than 0.7 (LogMar 0.18)) 6 months after FLACS with implantation of a trifocal IOL (PanOptix). IOL calculation was performed according to 7 formulas for each patient: Haigis, Hoffer Q, Holladay 1, SRK / T, Barrett II universal, Olson and Holladay II.

Results:

The calculated value (ME, MAE) significantly closest to the emmetropic refraction was received by the Olson (-0.31, 0.42), Haigis (-0.38, 0.39) and Barret II formulas (-0.40, 0.45), compared to the Holladay II (-0.67, 0.67), HofferQ (-0.52, 0.53), Holladay I (-0.61, 0.61), SRK / T (-0.47, 0.48) formulas (p <0.05).

Conclusions:

When calculating a trifocal IOL PanOptix, the most accurate results were obtained using the Olson, Haigis and Barret II formulas.

Financial Disclosure:

None

Back to Poster listing