Clinical experience with multifocal segmented bi-aspheric lens SBL-3 with 400 eyes on file
Session Details
Session Title: Pseudophakic IOLs: Multifocal II
Session Date/Time: Sunday 08/10/2017 | 10:30-12:30
Paper Time: 11:50
Venue: Room 2.1
First Author: : A.Janekova CZECH REPUBLIC
Co Author(s): : R. Zugar J. Pasta M. Janek
Abstract Details
Purpose:
A prospective study based on evaluation of 400 eyes of 204 patients was done in 4years. Both cataract and clear lens extraction patients were included. SBL-3 is hydrophilic acrylic presbyopia correcting lens. The availability of the lens is in 0.25 diopter power increments. The IOL power was calculated using SRK/T formula. Patients were evaluated postoperatively for distance, intermediate (70cm) and near visual acuity. A satisfaction questionnaire was administered 3 months after surgery. Patients were asked about photopic phenomenon such as glare and halos and evaluated spectacle independence in everyday activities.
Setting:
Eye centre Prague, Prague, Czech republic
Methods:
A prospective study based on evaluation of 400 eyes of 204 patients was done in 4years. Both cataract and clear lens extraction patients were included. SBL-3 is hydrophilic acrylic presbyopia correcting lens. The availability of the lens is in 0.25 diopter power increments. The IOL power was calculated using SRK/T formula. Patients were evaluated postoperatively for distance, intermediate (70cm) and near visual acuity. A satisfaction questionnaire was administered 3 months after surgery. Patients were asked about photopic phenomenon such as glare and halos and evaluated spectacle independence in everyday activities.
Results:
The percentage of patients who achieved uncorrected distance visual acuity of 0,8 or better was 90%, the percentage of patients who achieved 1,0 or better was 75%. In evaluation of intermediate visual acuity 81% of patients achieved uncorrected intermediate visual acuity 0,8 or better and 40% of patients achieved 1,0 or better. The uncorrected near visual acuity was 0,8 or better in 88% of patients and 1,0 or better in 60% of patients.
Subjectively patients report low levels of photopic phenomenons and high levels of spectacle independence in everyday activities for all distances.
Conclusions:
SBL-3 IOLs report excelent visual outcomes and low levels of photopic phenomenons. Patients receiving SBL-3 in current study attained very good uncorrected visual acuity at all range of distances and spectacle independence. Also preoperatively myopic patients that used to read without spectacles were very satisfied with the near vision after surgery.
Financial Disclosure:
NONE