Purpose:

To compare visual outcomes,optical quality, independence of glasses and visual disturbances in patients implanted with 2 models of monofocal intraocular lenses (IOLs)

Setting:

Private Gozakademi Eye Hospital,Denizli,Turkey

Methods:

Patients without ocular diseases and corneal astigmatism less than 0.75 diopters (D) had cataract surgery were included this study.Patients had cataract surgery with bilateral implantation of either of 2 monofocal IOLs, the Tecnis ZCB00 or the Tecnis Eyhance ICB00 (Johnson & Johnson Vision Care, Inc.). Twelve months postoperatively, monocular and binocular uncorrected and corrected (at 4 m) distance visual acuities, uncorrected and corrected intermediate visual acuities (at 66 cm) and near (at 40 cm) visual acuities were measured. Halo and glare perception, and independence of glasses were also evaluated.

Results:

A total of 100 eyes of 50 patients were evaluated in this study. Although monocular and binocular uncorrected and corrected distance and near visual acuities were similar between groups, monocular and binocular UIVA were significantly higher in the Eyhance group. There were no significantly differences between the groups glare and halo perception. The ICB00 IOL provided better independence of glasses than the ZCB00 IOL for intermediate distance.

Conclusions:

The Eyhance ICB00 IOL provided better uncorrected intermediate visual acuities and intermediate independence of glasses compared with the ZCB00 IOL