Posters

Search Title by author or title

Combined phacoemulsification and viscocanalostomy with Ologen implant vs combined phacoemulsification and viscocanalostomy

Poster Details

First Author: A.Samir EGYPT

Co Author(s):                        

Abstract Details

Purpose:

To study the efficacy of the biodegradable collagen implant Ologen® as an adjuvant in phaco-viscocanalostomy in patients with coexisting cataract and primary open angle glaucoma

Setting:

Slpha Vision Center, Egypt

Methods:

This prospective, interventional, randomized clinical study was done at Alpha Vision Center, Zagazig, Egypt. Patients with coexisting cataract and glaucoma were randomized to receive either phaco-viscocanalostomy (Phacovisco group) (39 eyes) or phaco-viscocanalostomy with Ologen® implant (OloPhacovisco group) (40 eyes). Follow-up period was 2 years. Nd:YAG laser goniopuncture was done in cases where the intraocular pressure (IOP) was elevated above 21 mmHg after discontinuation of corticosteroid eye drops at any follow-up visit

Results:

No significant operative or postoperative complications (other than failure) were encountered in either group. At 2 years follow-up, the mean IOP level was statistically significantly decreased in the OloPhacovisco group (p = 0.02) and complete success occurred in 23 eyes (59.0%) in the Phacovisco group and in 32 eyes (80.0%) in the OloPhacovisco group. There was a statistically significant higher success rate regarding complete success in patients that received Ologen® implant (p = 0.04).

Conclusions:

Ologen® implant improved the success rate of phaco-viscocanalostomy. Larger studies with longer follow-up periods may be required to confirm these findings

Financial Disclosure:

None