Information Registration Programme Overview Satellite Education Programme Virtual Exhibitor Listing


ePoster

All ePoster presentations will be available to view anytime throughout the Meeting in an Online Library

Search Abstracts by author or title

Title:

Unstable angle-supported anterior chamber phakic lens and secondary glaucoma


Poster Details

First Author: R. Maroto Cejudo SPAIN

Co Author(s):    R. Maroto Cejudo   N. Puerto Amorós   F. Gonzalez Lopez   A. Moreno Valladares   D. Espinosa Encalada   A. Moreno Martinez     

Abstract Details

Purpose:

To describe a case report of a secondary glaucoma caused by an unstable angle-supported anterior chamber phakic intraocular lens (IOL).

Setting:

Albacete University complex, Albacete, Spain

Methods:

24-year-old man with a history of refractive surgery (angle-supported phakic lens and lasik) for the correction of high myopia 4 years earlier, who presents high intraocular pressure (IOP) levels in his right eye (RE). Visual acuity was 20/20. IOP measured 26 mmHg in RE and 14 mmHg in left eye (LE). Slit-lamp examination revealed an angle-supported phakic intraocular lens that was slightly displaced in RE. Endothelial cell count was 900 cells/mm3 in RE and 1800 cells/mm3 in LE. He had a cup-disc ratio of 0.8 in RE with a diffuse optic nerve thinning consistent with a glaucomatous visual field defect.

Results:

Due to high IOP levels despite maximum medical therapy, non?penetrating deep sclerectomy was performed in RE with preservation of the IOL according to the patient�s wish. Months later, he returned to consultation complaining of episodes of hyperemia and pain related with physical activity. Slit lamp examination revealed a change in IOL position not manifested previously (comparing with previous anterior segment photographs). Axial length of RE was 30.7mm, higher in comparison with LE (28.10mm), and therefore consistent with a lens instability as the cause of these episodes. At that moment, it was decided removal of the IOL. The evolution was favorable.

Conclusions:

Glaucoma screening after refractive surgery is a challenging process. As tonometric accuracy is diminished, funduscopic and tomographic changes become more important. In a case of refractive surgery with implantation of an angle-supported anterior chamber IOL is important to take into account that in eyes with high axial length (higher than 30mm), angle-supported IOLs can be unstable and produce irreversible inflammatory changes in the trabeculum, and therefore apparition of a secondary glaucoma.

Financial Disclosure:

None