Warsaw 2013 Programme Registration Exhibition Hotels Virtual Exhibition Warsaw Satellite Meetings Visa Information

Examples of failed trans PRK

Poster Details

First Author: R.Smith AUSTRALIA

Co Author(s):    M. Kearns              

Abstract Details



Purpose:

These 2 case studies illustrate why transepithelial PRK is not recommended following previous corneal laser treatment

Setting:

: Sydney Eye specialist Centre, Australia.

Methods:

Two cases are presented where transepithelial PRK was used for refractive enhancement following previous corneal laser refractive surgery.

Results:

In both cases zero effect was achieved

Conclusions:

We concluded that the PRK treatments ablated only epithelium which was significantly thicker than normal as a result of previous laser treatment

Financial Disclosure:

None