First Author: AntonioLaborante ITALY
Co Author(s):
Purpose:
To evaluate the refractive outcomes: the best natural visual acuity (UCVA) , the best corrected visual acuity with lenses( BSCVA) and the topo-aberrometric data after 3 years from the execution of standardized laser-assisted lamellar keratoplasty descemetica.
Setting:
: Ophthalmology Department
IRCSS- Ospedale Casa Sollievo della Sofferenza
S.Giovanni Rotondo-FG ITALY
Methods:
They will be evaluated 10 eyes of 10 patients affected by keratoconus 3° stage. The patients were subjected to a Standardized Descemetic Intrabubble with the’aid of Femtolaser . For the data refractive analysis UCVA e BSCVA we used the ETDRS scale randomized survey and data were evaluated with by topoaberrometric analysis.
Results:
We performed a preoperative assessment after 1 year and 2 years and 3 years of UCVA average and BSCVA average, the sferoequivalent SE and topographic astigmatism average.
Ucva average 4/10, Bscva average 8/10, SE -1,65±2,25, Topographic Astigmatism average 2,60±1,50).The average astigmatism in Intrabubble is lower than Manual technique and also the percentage of success of the Bubble with Femtolaser is 85% in contrast to Bubble manual that is 65%.
Conclusions:
The first results showed a marked improvement in visual acuity after 6 months and greater stability compared to other types of cutting topographical. There is a good result residual astigmatism at 3 years. Furthermore, the fact of being descemetici allows a better recovery of visual acuity. FINANCIAL INTEREST: NONE