First Author: MoonesAbdalla EGYPT
Co Author(s): Ahmed Elmassry Osama Ibrahim Amr Said
Purpose:
To evaluate safety , efficacy and predectability of intracorneal rings(ICR) implanted using femtosecond laser in post keratoplasty refractve errors
Setting:
: Cornea center alexandria egypt
Methods:
prospective non comparative clinical trial .patients were ICR implanted by femtosecond laser( VisuMax ,Carl Zeiss Meditec) 6 eyes of 6 patients.Uuncorrected visual acuity (UCVA) , best spectacle corrected visual acuity(BSCVA), manifest refraction and K value were measured in all cases.
Results:
All these parameters showed statistically significant change in the postoperative period. (p<0.01).Mean preoperative Uuncorrected visual acuity (UCVA) , best spectacle corrected visual acuity(BSCVA), corneal curvature( k readings) were 0.1 ,0.7 and 53 respectively Mean postoperative UCVA,BSCVA,K, 0.6,0.9,48. 1 eye failed implantation due to perforation
Conclusions:
ICR can be a safe and effective and reversible way to correct irregular astgmatim FINANCIAL INTEREST: ... receives consulting fees, retainer, or contract payments from a company producing, developing or supplying the product or procedure presented