Ljubljana 2014 Registration Programme Satellite Meetings Exhibition Hotel Information Virtual Exhibition Visa Information
Back to Freepaper Session

Evaluation of a new multifocal intraocular lens with a lower near addition

Session Details

Session Title: Cataract II

Session Date/Time: Saturday 15/02/2014 | 08:30-11:00

Paper Time: 09:10

Venue: Gallus Hall (Level -1)

First Author: : FlorianKretz GERMANY

Co Author(s): :    Mary Safwat A. Attia   Katharina Linz   Anna Fitting   Gerd Auffarth     

Abstract Details

Purpose:

Clinical evaluation of two diffractive, pupil independent, multifocal intraocular lenses (MIOL) with a different near addition (Tecnis ZKB00 & ZLB00, AMO, USA).

Setting:

International Vision Correction and Research Centre (IVCRC)

Methods:

The ZKB00 and the ZLB00 MIOL with a near addition of +2.75 D and +3.25 D were implanted during cataract surgery and refractive lens exchange. Follow up examinations included: monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), distance corrected near visual acuity (DCNVA), corrected near visual acuity (CNVA) and individual reading distance and speed (Salzburg Reading desk).

Results:

1 month after surgery, the median monocular UDVA was 0.1 [logMAR]. Postoperative median monocular UNVA was 0.15 and binocular UNVA was 0.05. The patients were very satisfied with their outcome.

Conclusions:

The ZKB00 and ZLB00 MIOL with a lower near addition provide good functional results after surgery with a high percentage of spectacle independence and patient satisfaction. Especially the comparison of the individual reading distance and speed will be very interesting at the 3 month visit. FINANCIAL INTEREST: ... receives consulting fees, retainer, or contract payments from a company producing, developing or supplying the product or procedure presented, ... travel has been funded, fully or partially, by a competing company, ... travel has been funded, fully or partially, by a company producing, developing or supplying the product or procedure presented, ... research is funded, fully or partially, by a competing company, ... research is funded, fully or partially, by a company producing, developing or supplying the product or procedure presented, ... receives consulting fees, retainer, or contract payments from a competing company